A stillage foot is the short welded leg end that carries the frame to the floor — a plate welded to a collar, or a pressed foot slipped over the leg and welded around it. Where it fails is nearly always the collar: the ring of weld where foot meets leg. The base plate is almost always thick enough. The collar is where the load path turns ninety degrees, where welding has altered the steel around the joint, and where every fork entry puts a bending moment into a section that was drawn to carry compression. A replacement is therefore specified by collar, leg section and weld preparation — not by footprint and plate thickness, which are the two dimensions buyers usually send.
Stillage feet fail at the collar, not at the base plate; the plate is rarely the weak point, so measuring the footprint explains almost nothing about why the foot broke.
The consequence of getting this wrong is not a bad weld. It is a good weld on the same under-sized joint, cracking again a few months later.
Why the foot cracks and the frame survives
Four mechanisms account for most foot failures; they look alike in a photograph and need different repairs.
Fork entry is a bending load. A foot is a cantilever below the leg. The fork tip meets it before it meets the base, and the collar absorbs that as bending at its top edge. The stiffer the foot, the more impact goes into the collar weld. That is why the crack is a ring at the top of the collar rather than a buckle in the plate: the plate is in bearing, the collar is in bending.
The weld changes the steel around it. Welding leaves a heat-affected band either side of the joint that is not the material the drawing assumed, and on a coated unit it burns the coating away exactly where water stands. A foot finished before it is welded rusts from inside the collar outwards; a foot welded and then galvanised starts with its joint protected.
Dragging, not lifting. Loaded units get pulled across concrete rather than lifted, wearing the plate’s leading edge thin; a thin plate folds rather than cracks, so it fails as tearing rather than fatigue.
The repair that moved the failure. A heavier plate welded onto the original thin collar relocates the weak point instead of removing it, so the next failure appears beside the weld rather than in it.
| What you see | What usually caused it | What the replacement has to change |
|---|---|---|
| A ring crack around the top of the collar weld | Fork-entry bending plus a heat-affected band at the joint | Longer collar, thicker collar wall, longer weld leg or a small gusset |
| A crack starting at one edge and running across the plate | Foot landing on one edge — uneven floor, debris, or a unit standing on three feet | Larger plate, or a levelling foot; check the floor before the steel |
| Plate worn thin at one edge, then torn | Dragging instead of lifting | Thicker plate and a wrap-around leading edge, not a flat pad |
| Foot bent outward with the weld still intact | Impact, not fatigue; the collar is too short for the lever arm above it | Longer collar to shorten the lever, not a thicker plate |
| Rust starting inside the collar and spreading out | Coating burned off by welding; water trapped between collar and leg | Finish after fabrication, and a drain path so water cannot stand |
The five numbers a replacement foot needs
Every usable repair specification comes down to five measurements and one decision. A tape measure covers two of them; the rest need a caliper.
- Leg section — outside dimension and wall thickness of the tube the foot attaches to. If the foot has snapped off cleanly, measure the leg, not the broken collar.
- Collar — outside dimension and height, which together set the length of the welded joint. Collar height is the number most often left out and the one that decides bending resistance.
- Base plate — footprint and thickness, measured at three points, because a worn plate is not uniform.
- Overall foot height — floor to the underside of the frame. This sets fork clearance and stack height lost per tier, so it cannot be changed to suit a stock plate size.
- Finish and environment — powder coated, electroplated or hot-dip galvanised, and whether the unit lives indoors, in a yard, at a port, in washdown or in a cold store.
The decision is how the foot attaches: welded, bolted through the leg, or slipped over and welded. A bolted foot needs a leg end sound enough to drill; a split leg end needs a sleeve first.
A replacement foot is only as strong as the leg it is welded to; a thicker foot on a thinner leg does not strengthen the joint, it moves the failure out of the weld and into the leg.
What the thickness number actually means
Steel strip and plate are rolled to a tolerance, so “2.5 mm” is a nominal figure with a permitted range beneath it. Two suppliers can both quote 2.5 mm and ship different sections, and neither is lying. On a foot the collar wall is the section in bending, so that is where the number matters most; plate thickness matters mainly for wear.
Three habits make the question answerable:
- Ask for the tolerance in writing, not just the nominal figure.
- Measure the sample at three points on the collar and three on the plate.
- Specify the leg and the foot as a pair; a foot specified alone has no context, which is why catalogue feet fit badly.
If you are ordering new units rather than repair feet, the load rating must be agreed per model and per stacking height, not carried over from an earlier design. Our guide to specifying a stillage load rating sets out how to write that number down.
When a stillage should be replaced instead
Replacing feet is the cheap answer only when the frame is still true. Run these checks first.
- Check the diagonals. Measure corner to corner across the top and across the base. If the two top diagonals differ by more than a few millimetres, the frame has racked and the feet are symptoms, not the fault.
- Look at the deck. A deck that stays dished after the load comes off has yielded. New feet will not straighten it, and the unit will keep standing on three points.
- Check whether the leg end is intact. A foot torn out of the leg usually splits the tube, and a split needs a sleeve — a fabrication job, not a part.
- Count how many feet have gone. One foot in a fleet of forty is impact. All four corners on several units is a handling or floor problem, and new feet will not change either.
If the frame has lost its square, new feet will crack again — the load path is no longer vertical, and no foot section compensates for a leaning frame.
What we will not do
We do not sell single feet retail. Spare feet are supplied with new orders, or to existing customers on request. There is no online purchase, no one-off shipment of four feet, and no stocked part number to look up.
We do not issue load test certificates or compliance certificates. We are a steel fabricator, not a certification body. If your site needs documentation from a recognised testing authority, we are the wrong supplier, and the quality of the weld does not change that.
We do not copy a cast or proprietary foot from a photograph. We fabricate steel feet — plate, collar, tube. If the unit is an imported brand with a cast foot or an integrated castor yoke, the correct part comes from that brand, and a fabricated copy is not a functional substitute for a casting.
We do not work on personnel lifting devices. Forklift man cages and similar equipment are outside what we build or repair. A man cage lifts people rather than storage, and it sits under a different set of rules from anything on this site; the paperwork, not the steel, is the barrier, and we cannot supply that paperwork.
We hold no stock. A spare-foot order joins a production run — slower than a shelf pick, and the reason the drawing you send is the drawing that gets welded.
Who this is not for: a buyer who wants four feet next week for a unit bought elsewhere; a buyer who needs a certified part; a buyer whose real problem is a racked frame and who wants the feet replaced anyway.
How the foot is made
Tube and sheet are cut in-house, the collar and plate are robot welded, and the assembly runs through our own powder coating line with pre-treatment — dust removal, degreasing and derusting, drying, a 280 °C bake and cooling, about two hours for a single piece. Electroplating and hot-dip galvanising are the only two processes we send out.
We build to drawing, in overall dimensions of 500–6000 mm and a working load band of 300–3000 kg. Where a foot has to be galvanised, the sequence is fabrication first and galvanising after, so the joint is protected rather than painted over.
What to send
Send five things and you get a usable answer rather than a question:
- A photograph of the failed foot, in place, plus one of it removed.
- The five measurements above, or a sketch with them written on.
- The leg section, if the foot came off entirely.
- Whether the frame is still square, and how many units are affected.
- The environment and the finish you want.
Send it to ivy@fsyougu.com, or use the contact page if you would rather start with a drawing. If you are still deciding whether the unit is worth repairing, when a steel stillage is the wrong answer covers the cases where the honest reply is to replace rather than repair, and what is a steel stillage covers the frame itself.
Frequently asked questions
Why do stillage feet crack instead of bending?
Because a foot is a short cantilever welded to a stiff leg, so fork-entry impact arrives as bending at the top of the collar weld rather than as load the plate can spread. The weld also leaves a heat-affected band, and the crack follows it around the collar.
What thickness should a replacement foot be?
Match the collar wall to the leg it attaches to, then specify the tolerance as well as the nominal figure. A foot heavier than the leg does not strengthen the joint; it pushes the failure into the leg, which is a more expensive repair than the one you started with.
Can I replace just the feet, or does the whole stillage need replacing?
If the frame is still square and the deck springs back, feet alone are usually worth it. If the diagonals differ by more than a few millimetres, the deck stays dished, or the leg end has split where the foot tore out, the frame needs work and new feet will fail again.
Can you match the feet on an imported stillage?
Only if the foot is a fabricated steel assembly and we have its measurements. Cast feet and integrated castor yokes are proprietary parts, and a fabricated copy is not a functional substitute for a casting.
Do you supply spare feet on their own?
Spare feet are supplied with new orders, or to existing customers on request. We do not sell single feet retail, and we hold no stock, so a spare-part requirement is scheduled into production rather than picked from a shelf.
The foot has snapped off — what do I measure?
Measure the leg, not the broken collar: outside dimension and wall thickness of the tube, plus the floor-to-frame height from a unit still intact. If the leg end is split, say so — that turns the repair from a foot into a sleeve and foot.