A steel stillage load rating is the maximum working load — in kilograms — that one specific stillage design is engineered to carry, in one stated configuration: assembled and standing on the floor, stacked to a given number of tiers, lifted by forklift, or placed in pallet racking. It belongs to a drawing, not to a product category. Change the leg section, the span between the feet, the deck, or the number of loaded tiers, and the safe working load changes with it. At Foshan Yougu Storage Equipment we fabricate to customer drawings and state ratings across a 300–3000 kg band, so the useful question is never “what is a stillage rated for” but “what is this stillage rated for, in this duty”.
That distinction is where most specification errors begin. Two units with the same footprint and height can differ by a factor of three in working load, because one uses a lighter tube leg with a welded foot plate and the other a heavier section with a continuous base rail. Both look like a stillage; only one suits your product.
What a load rating actually describes
A rating is a statement about a configuration, not a material. Steel does not have a load rating; a welded frame standing on four feet does, and only under the conditions the designer assumed. Four configurations matter in a warehouse, and they produce four different numbers for the same unit.
| Configuration | What the rating assumes | What changes it |
|---|---|---|
| Static floor load | Unit on level floor, load evenly spread, not moving | Point loading, uneven floor, one foot unloaded |
| Dynamic (forklift) load | Unit lifted and travelled; forks carry the base, impact absorbed | Fork entry speed, off-centre lift, dragging instead of lifting |
| Stacked load | N loaded tiers bearing on the bottom unit’s posts and stack points | Tier count, load eccentricity, whether units interlock or simply sit on each other |
| Racked load | Feet or base rails resting on racking beams at a fixed span | Beam spacing, whether the feet land on the beams, beam deflection |
Two further qualifiers decide whether a stated figure is usable. The first is load distribution: a uniformly distributed load (UDL) and a point load are not interchangeable, and a UDL rating is optimistic if your product sits on a small pad in the middle of the deck. The second is the safety factor — normally at least 2:1 on the rated load, and higher on crane-lifted designs. Ask for the factor in writing: 2:1 and 3:1 on the same frame describe very different amounts of steel.
The structural factors that set the number
Six things decide what a stillage will carry. None is visible in a photograph, which is why comparing suppliers on appearance goes wrong.
- Leg and post section. Tube size and wall thickness drive buckling resistance; a taller unit needs a larger section for the same load, because the failure mode shifts from bending to buckling.
- Base frame and foot span. The base rail bends between the feet. Longer unsupported spans need deeper or thicker sections; this is usually the governing member on wide footprints.
- Deck type. Plate deck spreads load into the frame; mesh deck concentrates it at the wire crossings. A deck rated for a pallet is not automatically rated for a concentrated machine base.
- Weld design and consistency. A stillage fails at its joints far more often than mid-member. Robot welding gives repeatable penetration at foot and corner joints, a large part of why two similar-looking units behave differently under load.
- Bracing. Diagonals and gussets stop the frame racking sideways under a forklift turn. Remove them to save cost and the static rating may survive while the dynamic one does not.
- Surface finish — indirectly. Coating adds no strength, but corrosion removes it. In Australian outdoor yards, and on coastal or fertiliser-exposed sites, a finish that fails in three years quietly thins the section and with it the real rating.
All six are drawing decisions, which is the argument for buying from a factory that cuts tube, cuts sheet, robot-welds and powder-coats in-house with a pre-treatment line: the sections you specified are the sections that get welded, and a rating question reaches the people who set the welder. At Yougu the only outsourced steps are electroplating and hot-dip galvanising, so the structural side of a rating stays inside one plant of 7,000 m² and 89 people.
Why 300 kg and 3000 kg are the practical ends of the band
The band is not arbitrary: it brackets what buyers ask for, and its two ends behave differently.
| Working load | Typical demand behind it | Design consequence |
|---|---|---|
| 300–600 kg | Small parts, returnable packaging loops, retail and service-parts flow | Light section, mesh or part-plate deck, often collapsible; handling speed matters more than stiffness |
| 700–1200 kg | General palletised goods, mixed cartons, distribution centre replenishment | The volume sweet spot; standard footprints work, tiers usually three to four |
| 1300–2000 kg | Machined components, drums, mining and agricultural consumables, engine and transmission parts | Heavier base rail, gusseted feet, plate deck, fewer tiers because the stack gains load fast |
| 2000–3000 kg | Dense loads, long goods, sheet and billet material, high-density storage | The base and foot detail govern; fork entry and stacking method must be agreed, not assumed |
Above roughly 3000 kg the job stops being a stillage question and becomes a lifting and handling design question, with a different structure class and handling method. A supplier who offers 5000 kg on the same frame as a 1000 kg unit, without changing any section, is describing a sales process rather than engineering. Below 300 kg the constraint is rarely strength: it is durability and return freight.
How to write the rating into a drawing or an enquiry
A drawing that shows dimensions but not duty is ambiguous, and an ambiguous drawing gets built to the supplier’s own default. Supply these ten items instead:
- Working load per unit in kg, as the real maximum — not the average of a mixed pallet.
- Whether that load is uniformly distributed or concentrated, and over what area.
- Number of tiers to be stacked while loaded, and whether the bottom unit carries them all.
- Whether the unit will ever enter pallet racking, and if so the beam width it must sit on.
- Handling method: forklift, pallet truck, crane, or manual with castors.
- Footprint and overall height in millimetres; folded height if it must collapse for return freight.
- Deck requirement: plate, mesh, or mesh with a reinforcing rail.
- Surface finish and the environment it must survive — indoor, outdoor yard, washdown, cold store, coastal.
- Any feature that interrupts the frame: drop gates, half-drop sides, fork pockets, stacking posts, castors.
- Who confirms the rating, and in what document, before the first unit ships.
Item ten is the one buyers leave out and later regret. Put the rating in the purchase order against a stated configuration, and make any change to section, deck, tier count or footprint a trigger for re-confirmation. A rating that silently travels with a design change is worse than no rating at all.
What fails first when a stillage is overloaded
In practice the failure sequence runs like this: the foot weld or the base rail at the foot cracks or yields first, because that is where bending and lift impact concentrate; the frame racks out of square, which shows up as units that no longer stack cleanly; the deck deflects permanently, visible as a sag that does not spring back; mesh panels deform at the wire crossings; and only then does a leg buckle. A stillage that has lost its squareness is already at or past its working load, even if nothing has visibly broken.
How to verify a supplier’s claim before you commit
Ratings are easy to assert and hard to check. Check the process, not the number on the offer:
- Ask which member governs the rating — leg, base rail or deck — and what section it is. A supplier who cannot name the governing member has not calculated anything.
- Ask for the safety factor and the assumed load distribution in writing.
- Ask how tier approval is given: per model, or in general. It must be per model.
- Ask what voids the rating, and get that in writing too.
- For a first order, buy one unit, load it to the stated figure in your own yard, stack it as you intend to, then inspect the foot welds and diagonals.
- If your project needs independent load testing, appoint a third-party tester; we are a steel fabricator, not a testing body, and we do not issue third-party verification documents. We design to the rating and state its basis.
Because tube cutting, sheet cutting, robot welding and the automatic powder coating line with pre-treatment are all in-house, a change to the governing member is a production instruction rather than a negotiation with a subcontractor. We hold no stock and build only to drawing, so there is no catalogue default to steer you towards.
Where to go next
If you are still choosing a unit type, start with what a steel stillage is, then compare body types in stillage versus wire mesh container. If the unit has to travel, how to choose stillage size, load rating and container loading covers the freight arithmetic. For the range we build, see steel stillages.
Send a drawing, sketch or photograph with the load and stacking height written on it, and we will tell you which member governs, what section it needs and what the unit will be rated for. Email ivy@fsyougu.com or use the contact page.
Frequently asked questions
What is a steel stillage load rating?
The maximum working load in kilograms that a specific design is engineered to carry in a specific configuration — on the floor, stacked to a stated number of tiers, lifted by forklift, or placed in racking. It belongs to the drawing and the duty, not to stillages in general, so the same footprint can legitimately carry 400 kg in one design and 1200 kg in another.
Is the rating different when the stillage is stacked or lifted?
Yes, and the difference is large. A unit rated 1500 kg on the floor may be rated considerably lower when lifted dynamically, and lower again as the bottom unit of a loaded stack, because it then carries the tiers above it. Stacking height must be approved per model by the fabricator rather than inferred from the single-unit figure.
What safety factor should a steel stillage have?
At least 2:1 on the rated working load is normal, and 3:1 or higher on heavy-duty or crane-lifted designs. Ask for the factor in writing, and ask which member it applies to, because the same nominal figure on a different section describes a different amount of steel.
Can you increase the rating of an existing design?
Usually yes, by changing the governing member: a larger leg section, a deeper base rail, gusseted feet, or a plate deck instead of mesh. That is a drawing change, not a paperwork change, and it should be re-confirmed before production. Straightening or re-welding a damaged unit is likewise a re-rating event.
What load range can you manufacture?
Our stated band is 300–3000 kg working load, in sizes from 500 mm to 6000 mm. Within that band the rating is set by your drawing and your duty. Above it the unit becomes a different structure class with a different handling method, which we will say plainly rather than offer on the same frame.
Do you supply stillages with third-party load verification?
No. We design to the rating, state the governing member and the safety factor in writing, and build to your drawing. Independent load testing is arranged by the buyer with a tester of their choosing, and we support it with drawings and section details.