How to Choose Stillage Size, Load Rating and Container Loading


The four numbers that decide everything

Before a stillage can be quoted, four numbers must be fixed. Get any of them wrong and the unit will either fail in service or waste freight:

  1. Load per unit (kg) — the real working load, not the average
  2. Footprint (mm) — must match your racking beam width or your floor plan
  3. Stacking tiers loaded — decides the frame strength and the safety factor
  4. Return volume (folded height in mm) — decides freight per unit on the way back

Standard footprints and what they suit

Footprint Where it comes from Typical use
1200 × 1000 mm ISO pallet / UK-Euro hybrid, the global default Automotive, general industry, export
1200 × 800 mm Euro pallet EU and UK supply chains, retail DCs
1200 × 1200 mm Larger bulk loads Produce, bulk bags, cold storage
1000 × 800 mm Half-pallet Small parts, retail, light loads
Custom Racking beam spacing or product silhouette Long goods, sheet material, engines

Rule of thumb: if the unit will ever enter pallet racking, the footprint must be set by the beam width, not by the product. A 1200×1000 cage in a rack built for 1200×800 beams wastes 20% of the bay and can be unsafe if the feet miss the beams.


Load rating: static vs dynamic vs stacked

Suppliers quote three different figures for the same product. They are not interchangeable.

Rating What it means Where it applies
Static load Unit standing on the floor, not moving Floor stacking, long-term storage
Dynamic load Unit being lifted and moved by forklift Every handling cycle
Stacked load Load on the bottom unit when N tiers are stacked Warehouse density planning

A unit rated 1,500 kg static may be rated only 1,000 kg dynamic. When 4 tiers are stacked, the bottom unit carries roughly 4× the individual load — which is why stacking height must be approved by the manufacturer per model, never assumed from the single-unit rating.

Safety factor: industrial stillages are normally designed with a safety factor of at least 2:1 on the rated load, and 3:1 on heavy-duty or crane-lifted designs. Ask for the figure in writing.


Container loading: the calculation that decides your landed cost

Folded stillages are priced by the container, so the real cost driver is units per 40HQ, not the unit price.

A standard 40HQ has internal dimensions of approximately 12.03 m × 2.35 m × 2.69 m (about 76 m³). The number of units is:

Units = floor(12030 / L) × floor(2350 / W) × floor(2690 / H_folded)

Worked example — a collapsible stillage with footprint 1200 × 1000 mm and folded height 300 mm:

floor(12030 / 1200) = 10 → 10 along the container
floor(2350 / 1000) = 2 → 2 across
floor(2690 / 300) = 8 → 8 layers high
Units per 40HQ = 10 × 2 × 8 = 160 pcs

The same product assembled and shipped rigid would be 1,100 mm high, so only 2 layers fit: 40 pcs. That is a 4× difference in freight per unit — and the single most common reason a “cheaper” rigid stillage ends up costing more.

These are worked examples using standard container dimensions, not a specification of any particular Yougu model. At Yougu every size has a different load plan, because dimensions, folded height and unit weight all change with the design. Standard collapsible models fold to roughly 350 mm, but the exact figure is confirmed per model — ask us for the load plan of the specific unit you are considering.


Weight limit: the constraint nobody plans for

Container freight is limited by both volume and payload. A 40HQ typically carries around 26 tonnes of payload. Steel stillages are heavy, and the weight changes with every design: a higher load rating means thicker wire, thicker tube and a heavier base, so unit weight is always confirmed per model rather than assumed from a catalogue average.

At 160 units × 80 kg the payload is 12.8 t — volume-limited, fine. At 160 units × 180 kg the payload is 28.8 t — over the limit, and the container will be loaded short or refused. Always calculate both the volume fit and the weight fit .


The specification checklist to send a supplier

Copy this into your enquiry:

1. Product: stillage / wire mesh container / pallet cage / steel pallet
2. Load per unit (kg): ______ 3. Static or dynamic: ______
4. Footprint L×W (mm): ______ 5. Height (mm): ______
6. Stacking tiers loaded: ______ 7. Must it be rackable? Y / N
8. Collapsible for return? Y / N 9. Folded height limit (mm): ______
10. Surface finish: HDG / electro-zinc / powder coat (RAL ____)
11. Environment: indoor / outdoor / cold store / washdown
12. Quantity for first order: ______ 13. Destination port: ______
14. Any liner, divider, castor, logo plate: ______

A supplier who can quote from those 14 lines without asking a single follow-up question either has a standard product that fits, or is guessing. Ask for a drawing.

Foshan Yougu Storage Equipment Co., Ltd. produces stillages, wire mesh containers, storage cages, roll containers and steel pallets to buyer drawings at a 7,000 m² factory in Foshan, Guangdong — founded 2003, 500+ customers. We supply importers and distributors in Brazil and South America, New Zealand and Australia, Europe and North America.

Contact: Ivy Li, International Sales Manager — ivy@fsyougu.com | WhatsApp +86 13360306180 | Tel +86 757 29818173
Company: Foshan Yougu Storage Equipment Co., Ltd., No. 1 Beishui Industrial Zone, Xingtan Town, Shunde District, Foshan City, Guangdong, China


Frequently asked questions

How many stillages fit in a 40HQ container?
It depends entirely on the folded height. Volume fit is calculated as floor(container length ÷ unit length) × floor(container width ÷ unit width) × floor(container height ÷ folded height). A collapsible unit folding to 300 mm typically loads several times more units than the same unit shipped assembled.

What is the difference between static and dynamic load rating?
Static load is what the unit holds when standing still on the floor. Dynamic load is what it holds while being lifted and moved by forklift. Dynamic is always lower, and the forklift rating is the one that governs safe handling.

Can I stack 4 tiers fully loaded?
Only if the manufacturer rates that model for 4-tier loaded stacking, because the bottom unit then carries roughly four times the individual load. Never infer stacking height from the single-unit load rating.

Is 1200×1000 mm a standard stillage size?
Yes. 1200×1000 mm is the most widely used footprint for industrial stillages and mesh containers worldwide, alongside the Euro 1200×800 mm. Choosing the footprint your racking was built for matters more than choosing the cheapest standard size.

What surface finish should I choose for a cold store or outdoor yard?
Hot-dip galvanising. Electro-zinc coating is thinner and will not survive washdown, condensation or outdoor exposure for long; powder coating is for indoor use and branding rather than corrosion resistance.



Post time: 2026-11-13 18:11:33
[sharethis-inline-buttons]
INQUIRY NOW