A replacement stillage foot is specified by four numbers: the collar — its outside dimension and its wall thickness — the collar height, the base plate’s footprint and thickness, and the outside dimension and wall thickness of the leg the foot welds onto. Three of those four can be taken from the broken foot already in your hand. The fourth has to come off the cage, and it is the one buyers routinely leave out.
Three of the four numbers you need are on the old foot, not on the cage — and the missing one is the number that decides whether the new foot fits at all.
Measurement error is not a rounding problem. A foot specified from the wrong surface comes back the right shape and the wrong section: it welds on cleanly, passes a visual check, and opens the same crack a season later, because the joint is the same joint. What follows is only about taking the numbers; for why feet fail at all, our note on foot cracking and replacement specification covers the mechanisms.
The four numbers, and where each one actually lives
| Number | Where to take it | Tool | What a usable value looks like | What ruins it |
|---|---|---|---|---|
| Collar section — outside dimension and wall | Around the collar at three points, roughly 120° apart; wall at the open end with the burr filed off | Caliper | “60.2 / 60.0 / 60.3 mm, wall 2.3–2.4 mm” | Measuring across the crack, which reads oversize; measuring the wall through a weld bead |
| Collar height | Plate face to the top of the collar, on the least worn side | Steel rule | “45 mm, and the same from all four corners if they differ” | Measuring to the weld toe instead of the collar top |
| Base plate — footprint and thickness | Footprint at the widest point; thickness at three points plus the leading edge | Tape and caliper | “150 × 150 mm; 4.9 mm at the centre, 3.6 mm at the dragged edge” | Quoting the centre only, and losing the wear that caused the failure |
| Leg section — outside dimension and wall | The tube, 20 mm above the tear, where it is still round | Caliper | “50 × 50 mm, 2.4 mm wall” | Measuring the flared, torn end |
If the foot is a sleeve slipped over the leg rather than a plate welded under it, collar and leg sections come out nearly identical and the only number that separates them is the clearance — record both as measured, do not tidy one to match the other. If it is a flat plate welded straight onto the leg end, there is no collar and the height is the only vertical number on the part.
The number you cannot take from the broken part
Overall foot height — floor to the underside of the frame — is the fifth number, and the one a snapped foot cannot give you. The plate is usually gone or bent, so the stub tells you nothing about how much clearance the site actually runs. Take it from an intact unit standing unloaded on flat concrete, at a corner where the floor has not been worn into a hollow.
The foot height that sets fork clearance cannot be measured on a broken foot; take it from an intact unit, unloaded, on flat concrete.
This is the number that decides how a pallet jack or a fork tip enters, and how much stack height each tier gives up. Change it to suit a convenient plate size and the repaired units no longer stack level with the rest of the fleet.
Measure the least-damaged surface, not the most obvious one
Most unusable specifications are not sloppy — they are careful measurements of the wrong face.
- A worn plate. Measure the centre and the worn edge and write both down. A plate reading 4.9 mm at the centre and 3.6 mm at the dragged edge has been pulled across concrete rather than lifted, and ordering to the centre repeats the wear.
- A cracked collar. A crack opens the section it runs through, so calipers placed across it read large. Measure about 90° away from the crack and note where the crack was.
- A torn leg end. When a foot tears out, the tube flares outward and loses its section. Measure 20 mm up, and say in the same line that the end is damaged.
- A loaded stillage. A deck under load deflects, so any height taken from it reads low. Empty the unit, or state that it was loaded.
- Four corners treated as one. They are rarely identical. Record all four and let the drawing take the maximum and the minimum; averaging them produces a foot that fits nothing.
- A tape measure where a caliper belongs. A tape is fine to ±1 mm on footprints and heights and useless on a 2 mm wall. An approximate number with a stated method is workable; a confident number without one is not.
A measurement taken on the worn or cracked surface describes the damage, not the part.
The receiver matters as much as the part
A collar does not fit “a stillage”. It fits one tube, to a clearance, in one finish — which is why the leg section is not an optional extra.
An undersized collar leaves a gap that gets bridged with wire, and a bridged gap undercuts at the toe — the weld looks full and is thin where the load path turns. An oversized collar sits loose, distorts when pulled down, and leaves a gap that holds water. Both are drawing errors, not welding errors, and both are invisible under a coating. The workable instruction is a pair: “collar to suit 50 × 50 × 2.4 mm tube, 0.5 mm clearance, welded all round, drain path at the low corner”.
Finish belongs in the same sentence. A foot welded onto an already galvanised leg needs the zinc ground back locally and the joint re-protected; onto an already coated unit it burns the coating away where water will stand. That ordering is simple here, because galvanising is one of only two processes we send out — fabrication first, galvanising after.
A foot ordered without the leg section is a part looking for a hole; the pair is the specification.
What a usable record looks like
Send one page. It does not need to be neat, it needs to be complete enough that nobody has to ask you a question:
- One line per number, written as the range you measured, not the nominal figure you assume it started as.
- Which corner and which unit each value came from, with a photograph reference and the tool used.
- A flag on any surface that was worn, cracked or deformed when you measured it.
- Whether the unit was loaded or empty, and whether the floor was flat.
- The finish on the leg as it stands: bare, powder coated, electroplated or hot-dip galvanised.
- How many units are affected, and whether the failures share a corner.
- One dimensioned sketch with the four numbers written on it.
A sketch with three of the four numbers on it beats a perfect set buried in an email body, because the sketch travels to the welder and the email does not.
Where measurement stops being useful
Some feet cannot be specified by measurement at all, and the honest answer is to say so before a drawing is started.
- Cast feet and integrated castor yokes. We fabricate steel feet — plate, collar, tube. A fabricated copy of a casting is not a functional substitute for it, and no set of measurements changes that; the correct part comes from the brand that made the unit.
- A leg end split or flared past about one wall thickness. That is a sleeve and a foot — a fabrication job rather than a part.
- A frame that has lost its square. If the diagonals differ, new feet will crack again, because the load no longer travels vertically through them. The frame checks are in the replacement specification note.
- Anything needing a load test or a compliance certificate. We are a steel fabricator, not a certification body. We do not issue certificates, and a fabrication drawing signed by us does not stand in for one.
- Four feet next week, ordered online. We hold no stock and do not sell single parts retail. Spare feet are supplied with new orders, or to existing customers on request, so a spare-part requirement is scheduled into a production run rather than picked off a shelf.
- No way to lift or turn the unit. A photograph gives us the shape, not the section; a guess with a drawing attached is still a guess.
Who this is not for: a buyer who needs a certified part; a buyer repairing a racked frame; a buyer whose feet are a proprietary casting; a buyer who wants the part before the measurement.
From four numbers to a drawing
The numbers become a drawing before anything is cut — collar section, collar height, plate, leg interface, weld call-out, finish, and the clearance stated rather than implied. Tube and sheet are cut in-house, the collar and plate are robot welded, and the assembly runs through our own powder coating line with pre-treatment: dust removal, degreasing and derusting, drying, a 280 °C bake and cooling, about two hours for one piece. Electroplating and hot-dip galvanising are the only two processes we send out.
We build to drawing in overall dimensions of 500–6000 mm and a working load band of 300–3000 kg. Where a replacement has to match a load rating agreed for the original units, that figure has to be written down per model and per stacking height rather than carried over — our guide to specifying a stillage load rating shows how to state it.
Sending the measurements
Send the numbers, the photographs and the sketch to ivy@fsyougu.com, or start from the contact page if you would rather send a drawing first. If the reply is a question, it will be about the leg section or the finish — the two fields that decide whether the foot fits and stays fitted.
If you are still deciding whether the unit is worth repairing, when a steel stillage is the wrong answer covers the cases where replacement is the cheaper decision, and steel stillages covers the frames these feet sit under.
Frequently asked questions
Can I measure stillage feet with a tape measure?
For the plate footprint and the collar height, yes, to about ±1 mm. For a 2 mm wall, no — and the wall is the number that decides the joint. Send approximate numbers with the method stated and a rule in the photograph.
The broken foot is missing — what do I measure?
Measure an intact foot on another unit of the same model for the collar and plate numbers, then the leg section on the damaged unit 20 mm above the tear. If no intact unit exists, the numbers have to come from a drawing or from the brand.
Should I measure the foot or the leg first?
The leg. It is the receiver, and it decides the collar’s inside dimension and the clearance. Foot first and leg second is how a specification ends up with a collar filled with weld to close a gap.
How precise do the numbers need to be?
Half a millimetre on walls and clearances, one millimetre on lengths and heights. More useful than precision is the range: “2.3–2.4 mm measured” tells a fabricator which strip to pick, while “2.5 mm” is a nominal figure with a tolerance beneath it.
Can you work from a photograph alone?
A photograph gives us the shape and the failure, not the section. We can read where it cracked, whether it was dragged, whether the collar was ever long enough — but the calls still have to come from a caliper.
All four feet measure differently — which one goes on the drawing?
All of them. Record the maximum and minimum for each dimension and note which corner each came from. Feet drawn to one averaged value fit none of the corners, and the corner that differs is usually the one taking the impact.
Send the measurements to ivy@fsyougu.com and the reply will be a drawing or a specific question.
Post time: 2026-11-24